Architectural

Fire Rated Partition System

Fire Rated Sandwich Partition System
1,2 & 4 Hr Rating

Slim and Light weight

Impact & Water resistance

Up to 12m height approval using light weight channel stud support

Application – FR partition in humid area, over height partition tendency party wall etc.

Fire Rated Solid Partition System
1,2 & 4 Hr Rating

Slim & Light Weight, only 61mm for 4hr rating

Can be Install from one side

Application – FR wall with one side access only , Thickness of FR wall is critical ( footprint), increase the rating for existing wall , Seal off window opening

Promatect-S Fire Rated Partition System
1,2 & 4 Hr Rating

High impact resistance

Demountable

Replace masonry construction

Application – FR Demountable Wall, Shaft wall , Strong room

Fire Rated Ceiling System

Fire Rated Self-Supporting Ceiling System
1,2 & 4 Hr Rating

Fire protection from top & Bottom

Slim and light weight

Can be for final ceiling finishing

GFA (non lettable area)

Application – escape corridor, Lift lobby, AHU room etc.

Promatect-S Fire Rated Self-Supporting Ceiling System
1,2 & 4 Hr Rating

Fire protection from top and bottom

High impact resistance

Slim and light weight

Replace masonry construction

Application – Protected shaft such as escape staircase, demountable FR ceiling etc.

Fire Rated Self-Supporting Ceiling System
1 & 2 Hr Rating

Fire protection from bottom

Slim & light weight

Can be for final ceiling finishing

Application – Lift Lobby , escape corridor etc.

Fire Rated Suspended Ceiling System
1,2 & 4 Hr Rating

Fire protection from bottom

Slim & light weight

Easy to install

Can be for final ceiling finishing

Application – Lift Lobby , car park loading bay etc.

Fire Rated Structural Steel Protection System / External Cladding / Smoke Barrier

Fire Rated Structural Steel Protection
1,2 & 4 Hr Rating

Dry Construction

Mechanical Fixing

No pretreatment on steel

Neat and clean

Application – PPVC steel frame etc.

Fire Rated Lining for External Cladding System
Up to 4 Hr Rating

Single layer board

Unlimited Height & Length

Installation from one side

Application – FR Hording, Industrial building external wall

Fire Stopping for Curtain Wall System
Up to 2 Hr Rating

Light Weight

Easy to install

Neat and clean

Application – Use between floor slab and external cladding

Fixed Smoke Barrier / Smoke Curtains System
2 Hr Rating

Single layer board

Can be use as sign direction

Application – Atrium, large ceiling void

Fire Rated Access Panel / Hatches System / Load Bearing Floor

Fire Rated Access Panel / Hatches System
1, 2 Hr Rating

Easy to install

Up to 1m x 1m size

Horizontal & Vertical approval

Application – maintenance access on FR ceiling/ Partition

Fire Rated Load Bearing Floor System
Up to 2 Hr Rating

Dry Construction

Light Weight

Load Bearing up to 5KN/m2

Application – Load bearing floor for PPVC, light flaming housing or Hotel room, Mezzanine Floor etc.

Promatect-H Fire Stopping Panels
Up to 2 hr Rating

  • Suitable for Masonry or Drywall opening
  • Quick & Easy to Install
  • Vertical & Horizontal approval
  • Easy dismantling for inspection purposes
  • Application – Substation ramp / floor opening, demountable panel for compartment wall / ceiling